I saw one P&ID 6" control valve has been connected with 8"
process line, and 2" valve also connected in parallel with
6" valve. why the 2" valve connected in parallel, Is there
any technical reason. please clarify. With Regards-Kittu
Answer Posted / guest
any technical reason. please clarify. With Regards-Kittu
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?
few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters
what is function of switch, and how is it work, explain with difination
How many interlocks at turbine? Plz explain briefly
how to tune siemens sipart electro pneumatic positioner..plz tel me..
I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann
components of control circuit belongs to control valve
How to Calibrate Temperature Switch in field
Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure
What is wet leg condition and why is it used?
What is ultrasonic flowmeter?
what diffrence b/w plc s7200,300,400
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
What is instrumentation measurement?