how can u say about the line by looking at the tower ?
{voltage rating of the line}
Answer Posted / ujjwol
Just like the other people said, counting the number of insulator will give you the idea of voltage level of the line. If there are 6 insulators, it is basically 66 kV and if there are 9 insulators, its 132 kV and so. If the tower has horizontal configuration , then u can almost predict that the voltage level exceeds 200 kV. It is because horizontal towers are used for voltages exceeding 132 kV ,to reduce the height of tower.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
Is the installation of the filter cloths necessary before spreading the gravels at the transformer yards?
How can calculate the rating of a alternator for a given specific load with formula
Do any one know exacatly when the results for NHPC held on 8th march 09 for engineering trainees will be released ?. if so please post it, i'm eager to know it.
What is meant by derating factor?
what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that
How to determine stage of Automatic Power factor controlling Relay(Apfcr)?
why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor
For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
how we design a pannel to start 10HP motor with the help of star delta starter?
Why do we apply both Differential and REF (HV and LV) protection schemes on YNyn configuration of a transformer?
how to design coil turns ?
solor panels arrange some angle,panel is flat fitted energy was produced or not why?
"TRANSFORMER MODELING AND ANALYSIS" MEANS WHAT AND WHICH TOPICS U READ IN THIS
I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?