what is the use of conservator in a transformer?
Answer Posted / s.murugesan
Two main roles of conservator:
1) Due to temperature variation the transformer oil
volume varied it was compensated by conservator and will
allow pure air inside the TR.
2) To maintain the oil level inside the
transformers.
| Is This Answer Correct ? | 12 Yes | 1 No |
Post New Answer View All Answers
Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel
WHAT IS THE PARTIAL DISCHARGE TEST?
Where can i get practical knowledge of solar system?
how to wiring it with contactor and timer together
how to calculate earth fault relay current and CBCT ratio
why lightning arrestor are made in two stack of insulator but why not cvt
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
Direction of flow of active power and reactive power with logic?
What are the different sign conventions used in electric circuits?
54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?
i have some screw comprressor with 630kw power,i have established them with simple star to delta circuit,by the way there is so much inertia when the screw comprressors start, can you offer me contactors power with 400vac or any cataluge to choose the contactors
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?
what is difference between isolation and ultra isolation transformer?, what is the method of testing ?
how can maintaince the acb contactor moveing and fixing kit