At present how many HVDC lines are there in india
Answer Posted / gandhi pratik
at present in india there are three operating HVDC
transmission lines(not including B-to-B)
1)chandrapur to padghe(mumbai)--(1500 MW at ±500 kV DC)
2)rihand to delhi (dadri)(1500 MW at ±500 kV DC)
3)talchar to kolar (2500 MW)
and projects in progress are:
4)ballia to bhiwadi(2500 MW)-first pole charged as of 31st
March 2010
5)Mundra-Mohindergarh(Adani group-first Indian private
HVDC)-in progress,completion by 2011 end.
6)Bishwanath/Chariali to Agra(6000 MW)-recently awarded to
ABB-BHEL
Is This Answer Correct ? | 20 Yes | 13 No |
Post New Answer View All Answers
what is differentila pilot supervision in the incomer control panel in the power station?
What are differences between Voltage, EMF & Potential difference ?
Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?
What is the difference between multimeter
show the single line diagram of star delta starter with single phase preventer
What determines the thickness of the lamination or stamping?
when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil
What is the purpose of stablization resistor in high impedance bus bar protection
how we arrange the hv side with delta connection in case 33/11kv of transformer.
what is the working principle of energy saver control panel. please give the complete calculation & theory.
any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?
how to calculate magnetic force genrated by a coil ?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
How you will determine the volume of oil in a particular Distribution transformer.