Answer Posted / roysayan01
Sum of Individual Max. Demands
diversity factor=--------------------------------
Max. Demand on Power Station
Higher the diversity factor the better will be the load
factor and hence electrical energy will be cheaper. Some of
the loads have inherent diversity eg- the lighting load is
at its peak when industrial load is minimum.
Is This Answer Correct ? | 6 Yes | 2 No |
Post New Answer View All Answers
What is the rating factor for copper cable ( Specific value according to the type of laying ) & the voltage drop?
What is the unit of charge and current?
state the disadvantages of carbon filament???
what is the condition for YnD11
Why is ignitor used in sodium vapour lamp
what is meant by residual over voltage & residual earth fault ?
5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What is routh hurwitz stability criterion?
The SFC of an engine is 0.25 kg/kW hr. when the fuel used has a calorific value of 36000 kJ/kg. the thermal efficiency of the engine is
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
what are the difference between PLC and embedded
How can I calculate the Mega watts required to run a plant having many electric motors and other electrical components.
what is the role of energy meter in distribution system ?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?