What is the difference between local indicator(flow) and
flow indicator?
Answer Posted / ramesh dham
Flow Indicator/ Totalizer Not just a digital indicator but it is a flow calculator. In Flow Totalizer three inputs are taken (DP, Pressure & Temperature).It make density correction for volumetric flow to make them mass flow.
Local Indicator for just display of Flow can be of any digital indicator with 4-20 mA input.
Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
Explain PID, ON/OFF, Controls
State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.
A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.
What is megering????
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.
What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?
Introduce yourself which is not present in your biodata?
what is output of FOUNDATION FIELD BUS transmitter
What is the cascade control
Boolean algebra
Why are the uses 24vdc in industries
can we create an interrupt in plc through scada?