If we feed 230V ac supply to a full wave rectifare, what &
how much will be the out put voltage?
Answer Posted / rajesh tewari
it is depending upon firing angle of thyristor. how many we
requres in output.we make the thysistor as we need.
Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
is that any software calculator to calculate the size of cable
how to identify vector group of three phase transformer by voltage method?
How does an oscillator differ from an amplifier?
what are the problems that generally occur in power flows??
how unidirectional torque is produced in DC motor?
why you don not show protection and type of isolation in key single line diagram?
How to reduce the static electricity producing in solvent room? By P.D.Patil BioCon
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet
Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???
in an electronic tri vector meter when the current and voltage sequence changes ? what is the effect of phase sequence on recording of meter
What is the range of the stator resistance of 3 phase induction motor?