Whats meant by trivector meter where it is connected at the
substation?

Answer Posted / aneesha

trivector meter is a divice that measure the amount of
electrical energy supplied to or produced by
residence,bussiness,or machine.The trivector has automatic
self diagonostic check.In the absence of supply,it provides
even minute reading.

Is This Answer Correct ?    1 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

1747


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1288


what is the disadvantages of common earthing for AC and DC equipment? (i am talking about inverter control room and inverter duty transformer earthing is common...?)

1189


What is the maximum percentage voltage drop (vd%)for a motor control center

1553


What is the Nyquist criterion regarding control systems?

663






ROC converges if pole and zero lies inside a) origin b) z=1 c) pole d) zero ? Explanation please? if ROC does not converges then?

2465


pls someone send me sample question papers along with the key.thanks in advance

1891


1.what is the reason for transformer and lightning arrester blast in 33kv system

2583


for 750 kw LT load what will be the ht kva

1251


how does commutator convert a.c to d.c?

1770


The windings of a transformer are divided into several coils, because?

816


why do we not use equivalent voltage source in negative sequence equivalent ckt.

1612


Briefly describe means used by electricity suppliers to influence the flow of active and reactive power in power networks (one for each type)?

1513


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

4490


Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????

1389