if 40 watt bulb has higher resistance then a 100watt bulb
then according to joul farmula p=I^2R the 40 watt bulb more
power consume then 100 watt bulb.
Answer Posted / joydeep kr. chakraborty
The Joule's formula P=I^2R holds good only if I through
them is Constant. But, when connected accross same voltage,
the current through a 40W bulb is less than a 100W bulb.
Thus, I^2R for 40W bulb will be much much less than that of
a 100W bulb.
If we connect them in SERIES and apply voltage to the
combination, the current passing through them will be same,
and in that case, the 40W bulb will definitely CONSUME MORE
POWER THAN 100W BULB.
| Is This Answer Correct ? | 5 Yes | 4 No |
Post New Answer View All Answers
What is a surge supressor why its is used in synchronous generators
Why using synchronising methed in DG's sets?
Why in ESP Positive earthed
Explain marx circuit.
what is the difference betweem star connected motor & delta connected motor?
what will happen if there is a voltage leakage or current leakage in an electrical train
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above
RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?
please write motor, transformer, Generator setting, fault level calculation of Tr.etc
How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.
For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is
For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?
what is meant by LCR meter? where its useful ?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
whats the differece between Exd and Exe