THE ROTIO OF VOLTAGE AND CURRENT IN A CLOSED CIRCUIT

Answer Posted / madhusudhana

The ration of V to I in a closed circuit is constant. It is one of the question asked in written exam.

Is This Answer Correct ?    37 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..

1492


Define closed loop control system.

654


WHAT IS THE FORMULA FOR CALCULATING CURRENT RATING(DIRECT IN GROUND OR AIR) OF ARMOURED(XLPE) CABLE OF 4C,16Sqmm?

1660


sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason

1039


When lag/lead/lag-lead compensation is employed?

739






i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value

1421


What is the typical enclosure type used for Indoor switchgear / Outdoor switchgear Units? - In Onshore / offshore Units?

538


how to erect roof control panel?

1540


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

1741


As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.

1396


What is a signal flow graph?

647


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2014


How do you compute voltage drop and cable size over distance?

1761


i am venkat i got gre 930(verbal 270 quanta 660) and my toefl score 105..here question is why u got less score in gre ? what i supposed to tell...any chance of rejection is there...my accadamics record is very good

1733


What is corkscrew rule?

682