What is C.T, why it is used and what care should be taken
for that while connecting?
Answer Posted / sachin lakhe
C.T means Currents transformer which works as normaL
Transformers use to mesure current in primary.
we r using coil to show the current in ratio.
Exa- 400/5 means if primary is 400amps then secondry will be
5amps.
Just we r making suitble current for ameter coil.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Why does curving the pole faces in a dc machine contributes to a smoother dc output voltage from it?
Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.
How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
what is the responsibility of C license holder in industry?
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above
1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating
some basic standard questions on transformer.
what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....
why the neutral line is not giving shock to us if we touch it ?
what is ground fault in ACB?
What is inrush current? how can calculateit? what is the affect of it?
why in the three pin plug all 3 pins are cutted ?