What is mean by Ethernet, Device net and Control net? For
what application we are using these?

Answer Posted / santu dhar

Eathernet is a hub which use to splite one network input in
more output. the number of output is depends on the number
of port.

Is This Answer Correct ?    0 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Conversions

1672


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

1776


why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature

1372


What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?

729


In power plant to measure vibration of a turbine we install sensors. Before install this sensor we have to set gap voltage. What is meant by gap voltage and its use?

1613






Why mixer nd grinder Is example of constant torque load not variable torque load ???

1492


Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.

1495


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4166


1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.

2217


what is the imbustion control loop

1432


how to calibrate Necleuonic level transmitter.?

1640


Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .

1191


Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...

1895


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

1627


why we are using digital signals for I/O & how to measure this signals is getting or not ?

1536