How we can calculate what type of supply we need for an
example sometimes we take 11 KV and sometime 33KV from EB ?

Answer Posted / raghavendran

Power is transmitted at various voltages like 11,33,66,110KV
,230kV and 400KV in our country.In order to reduce
transmission line losses we prefer high system
voltages.Hence (1)if the distance is longer and also(2) if
an industry consumes power from 33kv system,33kv voltage
transmission system is availed.other wise we go for 11 kv
system depending upon our requirement as stated above.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Write the analogous electrical elements in force voltage analogy for the elements of mechanical translational system.

738


wow to calculate the transformer rating(KVA)

1685


A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

1888


How the setting of the vector surge relay shall be calculated when the relay is to be used for Grid islanding application?

1798


is there any lightning by passer is arranged in ship like buildings?

1478






what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

7133


what do you mean by plant earthing system.

1548


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1671


What is mean by STUB protection?

1581


How many VSC based HVDC are there in India and the world

1759


what is allowable ac mixing in dc

1542


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

1728


TYPE'S OF BREKAR ,WHAT IS TRANSFORMAR & SAFTY. STARTER DOL & STAR DELTA STARTER.

2110


why effective resistance should be more than static resistance in transmission line?

1592


why power factor is important?

8342