in trains i have seen the terminal which is connected at
the top of the train is positive .where is negative ?
track? i dont think so
Answer Posted / shashank
Dear All,
Not all traction systems work on AC supply. Wherever there
is a DC supply used, the return path is providedby the
earth i.e. the ground. Now comming to the vasics of
electrical engineering, Voltage is a unit for the Potential
diference (PD). PD itself says that there needs to be a
difference in the potential of both the electrodes for the
current to flow. It is not only that if the OHE has +ve
potential the system will work but even if the OHE has -ve
potential then also the system will work as automatically
the earth becomes the +ve eletrode.
But Indian railway uses +ve supply with referance to the
earth, hence we dont ger a shock as already the potential
is zero.
Whereas the AC Supply is concerned i agree to what manesh
has said. with the only addition that the neytral is
grounded i.e. earthed.
Shashank
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
I am inpecting a 10kVA UPS what tests should i do and should i observe?
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
What is the instrument to check the rotating diode fuse of alternator in running conditions?
How would you relate your key competencies to this position?
Transformer how to maintaince a check b check c check d check
xfhnchncv?
what will happen if frequency is below 50 hz?
how braking & making capacity of circuit breaker is calculated?
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?
Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.
how meger function
How to check the cable fault / hv test of transformer cable.
how does the terminal voltage of transmission lines increase when a capacitor is connected???? This happens not only in transmission lines but also in all circuits. How??? When a capacitor is connected in a transmission line, capacitor also takes energy from the same supply. But how is it able to increase the terminal voltage??? Practically What sequence of events happen during increase in voltage???