Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is AVR in Generators and How is it working.

Answer Posted / satyanarayana raju

AVR MEANS AUTOMATIC VOLTAGE REGULATOR.AVR IS HAVING TWO
INPUT TERMINALS AND TWO OUT PUT TERMINALS OUT PUT IS GIVING
DC VOLTAGE .IT IS CLOSED LOOP CONTROL SYSTEM. I WILL
GIVE ONE EXAMPLE . AVR HAVING TERMINALS LIKE S1,S2, AND
F1,F2. S1 AND S2 ARE INPUT TERMINALS THAT IS CONNECTED TO
OUT PUT OF THE ALTERNATOR VOLTAGE. F1 AN F2 IS CONNEDCTED
TO FIELD OF THE EXITER TERMINALS. I WILL EXPLAIN HOW IT IS
WORKS. EXITER IS COUPLED WITH ALTERNATOR ROTOR. EXITER
FIELD IS HAVING OWN RESIDUAL MAGNITISUM DUE THIS MAGNETISUM
ALTERNATOR GETS SMALL VOLTAGE THAT IS AROUND 10-20VOLTS AT
OUT PUT VOLTAGE. U WANT SEE THIS VOLTAGE REMOVE F1 AND F2
CONNETIONS CHECK VOLTAGE AT OUT PUT TERMINALS. THESE OUT
VOLTAGE IS SENDING TO AVR INPUT TERMINALS THAT IS S1 & S2
THEN AVR GIVES SAME VOLTAGE TO EXITER FIELD THEN EXITER
FIELD GIVES MORE MAGNETISUM DUE TO THIS ALTERNATOR GIVES
MORE VOLTAGE AGAIN THIS VOLTAGE GIVEN TO AVR LIKE THIS
THESE CYCLES GOIES ON UP REACH REQUIRED VOLTAGE OF THE
ALTERNATOR. AT REACHING OUT PUT REQUIRED VOLTAGE AVR IS
NOT SENDING MORE VOLTAGE TO EXITER THERE IS CUTT OF SET
POINT . WHOLE THESE CYCLE TAKEN VERY LESS TIME MEANS MAY
BE 1 SEC. AVR OUTPUT VOLTAGE IS DEPENDS UPON THE COMPANY OF
THE AVR AND REQUIREMTNT OF THE ALTERNATOR. HELLOW FRIENDS
IF U HAVING LITTLE BIT KNOWLEDGE IN ALTERNATOR SIDE U
CHANCES A UNDER STAND THIS INFORMATION IS VERY EASILY. IF U
WANT MORE INFORMATION AGAIN CALL BACK . THNAKING U

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

all details of DG UPS HVAC

2093


what is allowable ac mixing in dc

2117


Please tell me the power flow from pmg to main rotor of an alternator (Including AVR unit)?

2047


how does this job compare with others you have aplied for?

1661


How much depth n width required for laying of 1X70 Sqmm Cable in Desert???

1624


What is the formula to calculate distribution transformer De-rating on iron losses basis

1861


what is difference between elr and R eartl realy.

2658


full form of electrical?

2730


how to find Harmonics and types as per the equipemnts

1305


I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.

2079


Should power factor be low or high?

1187


what happened when we supply a dc current in dc motor?? can it worked properly?

1966


plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?

2316


Why open circuit test of transformers is conducted at rated voltage??Why not any other voltage??

1679


hi frds, i m electrical engineer.can i get cdr for electrical engineer if u have then send me on my mail id its jayesh_ee88@yahoo.com.please help me frds

2206