what is the function of commutator in dc motor?
Answer Posted / dharmesh
commutator function in the dc motor is to convert dc
quantity into ac, so it produces regular torque.
& in case of generator it converts ac quantity into dc.
THE FUNCTION OF COMMUTATOR IN DC MOTOR IS TO REVERSE THE
DIRECTION OF CURRENT.
thank you.
| Is This Answer Correct ? | 38 Yes | 8 No |
Post New Answer View All Answers
Difference of induction motor & servo motor ??
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
how we test a 3 phase motor on single phase supply....? HOW WE RUN A 3 PHASE MOTOR ON SNIGLE PHASE. supply for testing..? how we verify of a 3 phase motors 6 wire & name thame a1/a2/a3..b1/b2/b3 and c1/c2/c3 for connecting star delta starter ........i have only 1 phase supply ? help forum..........
what is photo voltic cell,& what are the materials associated with that?and any spcifications like volts/cm etc?
DG cranking voltage?
For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?
1.what is the funtion of chiller primary & scondary pumps. 2.what is the use of distribution lines & Types. 3.what is the use the thermal power stations & how much capacity.
What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?
What is servo motor and what are the applications of servo motor?
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.
How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
what is the safty of poly phase tranformer?
Is it true that in the 3 phase transformer, the limbs of the core are at 45 dgrees to each other. if true, why?
What is the function of Governor in Hydro Power Station? What is the Function of Lightning Arrestor Voltage Transformer (LAVT)?