HOW TO FIND THE PRIMARY AND SECONDARY OF TRANSFORMER(IN OFF
CONDITION) USING MULTIMETER? IS IT POSSIBLE FIND BY SEEING
RESISTANCE???

Answer Posted / rsbangra

As looking the tranformer one side primary and other side
secondary as per name plate, we can mesure resistenance by
just r=v/i v=rating voltage and i= rating current ,voltage
take root 3 of line voltage, so we recive resistanse value
ht or lt side, as other view insulatior are used ht side so
high and lt side lower leanth and small size.

Is This Answer Correct ?    3 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what purpose to use excaiter in DG.?

2211


what are the differences between 'exhaust fan', 'heavy-duty exhaust fan' & 'super heavy duty exhaust fan'. what are their power ratings ?

1555


What is the types of HT motor testing

3001


Define the term Capacitance and Inductance?

642


How to know of any cable size if there are not written on cabl?

1432






A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

4474


Why do we need interlocking in a HT metering or Ring main unit switchgear?

1554


IN electrical field, WHAT ALL THINGS THE CUSTOMER WILL ASK WHILE ORDERING FOR LT PANEL (ALL TYPES OF LOW TENSION PANEL)

1624


What is the distance between body earthing and neutral earthing.?

4086


what is your aim

1436


How the circuit breaker is selected for Induction motor of 100 kW, 415 volt, 0.85 power factor, 0.95 efficiency ?

1212


what is the function of capacitor duty contactor in an capacitor panel???

3610


what is load vs Torque curve & why it is used?

1578


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1354


List the characteristics of filter?

612