Why fuse is? What will prevent by fuse?

Answer Posted / desingurajan ramco cements...

Fuse not having low melting point..... it is always having small thickness when compare to wherever it is connecting in the conductor.... CURRENT MEANS FLOW OF ELECTRONS...... when any faults occurs (like, short circuit..etc) more electrons flow through the fuse compare to normal running condition. that time more electrons not able to flow through the small area(ie fuse). at the time fuse will be over heated. and it will melt. and proper fuse wire having aprox 800C. melting speed is based upon the fault level......

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 2083kva AVR was tested, phase to ground shows continuity, what is the implications

513


either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?

1421


what is the Earth Voltages in Power Plants, Sub-stations, Industries, Residential & Commercial Buildings.

1655


What is slope...? Explain slope 1 and slope 2...?

1076


a starter used for squirrel cage induction motor?

1210






i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?

3062


How to Prepare preventive maintenance shedule of machine tool.

1521


typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?

1294


delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?

1536


why dc is used in control circuits for MV & LV switchgeras instead of ac

1471


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

1774


WHAT WOULD BE THE FORMULA OF WIRE GAUGE FOR A FULL LOAD CURRENT

1688


What is the formula to calculate a three phase alternator

1782


What is meant by sag?

651


what a function diesel generetaor turbo charger & turbo charger is more heated explain reason ?

1812