What is mean CT Saturation? How to calculate?

Answer Posted / sumit jha

ct saturation is a condition when the secondary gets open
circuited & so there is no provision of counter balancing
the huge mmf produced due to enormous line current in
primary & so secondary must be connected to the coil of
metering element.& never left open..............

Is This Answer Correct ?    8 Yes 26 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is different between Circuit breaker and Isolater?

1224


Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?

1039


hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.

2466


2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping

1455


What are test signals and their significance?

632






In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

359


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1342


How to calculate ant test the burden of Current transformer

1956


What are reasond for high wattage in single phase induction motors

1375


Write down the design procedure of commutaj.

1724


Why do we need interlocking in a HT metering or Ring main unit switchgear?

1563


Name two low frequency oscillators?

901


Explain the role of a car driver as one of a feedback mechanism.

738


1sq mm dc powr cable can carry how much dc currnt

1491


what should be correct gas pressures to be a 1.5 ac unite

1076