Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is neutral grounding? why is it required? what is
neutral grounding resistor and how is its value calculated??

Answer Posted / maruthi gh

what he said is write

Is This Answer Correct ?    7 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?

1660


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1748


How to calculate VCB rating for 33KV ,25 MW Power line?

1754


What is the selection process of breakers. Can any one please give a formulation on same?

2165


why ht motors are star connected?

1882


in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?

1921


If we use 250A MCCB as a incomer in Control panel for a fault level of 50kA for one second ,assuming temperature rise from 85 Deg. to 100 Deg , Then what will be the Aluminium Bus-bar size for 250A MCCB? Explain in detail.

2347


what is counter poise conductors

2167


What is the purpose of stablization resistor in high impedance bus bar protection

2013


what are the parameters plays a major role in Potential transformer Burden calculation??

2203


what is mean by parallel operation of permanent magnet generators

2002


in science exhibition how lamp can blink when you clap near the lamp ? thank you

1992


What is the current carrying capacity of 0SWG,3SWG,10 & 12 SWG solid bare overhead copper conductors?

3451


How PSV sizing being done

2336


Which types of gate insttaled in static switch. Please give me answer.

1631