If we touch the Capacitor terminals you feel shock after
the capacitor was put in operation and not in case of
inductor though both are energy storage elements.why?
Answer Posted / praveen kumar.bodu
In a circuit capacitor discharges through RC time
constant.i.e. capacitor discharging is mainly depends on
resistance of the circuit. human has some resistance when
we disconnect the charged capacitor it dischares through
human resistance when human touches its leads.then we felt
shock.
But in case of inductor the discharging takes place in
form of flux.so human cannot feel any shock with the flux.
| Is This Answer Correct ? | 5 Yes | 2 No |
Post New Answer View All Answers
Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?
What are the advantages of using distance protection schemes as opposed to normal overcurrent/ earth fault protection on high voltage feeders.
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
How many types of probe used in cro?
what is meant by twilight switches 7 where its applicable ?
When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?
single phase power supply give to separate one steel coup with water, what reaction create
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
what is earthing.how we make it,describe briefly.
why single CT used in DOL starter power circuit?
The ripple frequency in output of fullwave bridge rectifier is a. Half the input b. Twice the input c. Same as input
list the type of vfd? wich is sutable for heating kiln?
HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?
what is the advantages of having in-built acvvvf (without seperate inverter in the control panel)in the drive system of elevators?
Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit