What is latent heat of melting?
What is latent heat of vaporization?
What is difference b/w steam, wet steam, saturated steam
and superheated steam?
What is relationship of boiling point and pressure?
What is mean by HP steam?
What is function of HP steam system?
What are main components of HP steam system?
What is function of steam strainer?
What are conditions for opening of warm up control v/v
LBA10AA050?
What are conditions for opening of turbine control v/v?

Answer Posted / jayaa

latent heat is the heat released or absorbed during the
phase transformation. wet steam is mixture of liquid &
vapour. sat.steam is steam at sat temp. super heated steam
is steam heated above sat. temp.
pressure is directly praportional to the temp.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to report calorific values of fuel?

631


Which material amoung EN8 and EN24 should be selected for the designing of the shafts of rotary kilns

1104


What are the different theories of failure under static load, explain ?

717


What is the purpose of air blow?

1600


What is the critical speed. Compare the critical speed of hollw shaft and solid shaft.

2129






If 320 grade Gear oil is used in a reduction gear box,what can be themaximum operating temperature of the gear box?

1602


What safety device will activate to stop the compressor in the refrigeration system

1723


tell me about a time when u had too many things to do and u were required opinion prioritized your talks

1347


how can I calculate daya of pump

1366


where i can get APPSC AEE(Mechanical Engg) previuos question papaers

2608


What is the critical temperature of a refrigerant ?

620


My vendor filled liquid oxygen in our 11000 liter capacity tank. He filled from 1400 MMWC up to 3200 MMWC. I followed the provided conversion table and found that we had been supplied 1800 MMWC liquid which is going to yield 2815 cubic meter. On the other hand, the vendor claims that he supplied as follows:- 5236 cub mtr(3200 MMWC)-2124 cub mtr(1400MMWC) = 3112 cub mtr. I fear that he wants to charge 297 cubic meters extra. He claims that my method was wrong and his was right. He says that this disparity is because of the conical shape of the base of the flask. I will be thankful if somebody can explain me the truth.

2897


current rating of a 3 phase dg set is 20 amp, but what will be the per phase current for single phase supply?

1776


Why is over-pressurizing an air conditioning system bad?

576


how to change numbering in SAP script i.e. i have 1245.00 now i want to specify in word in script i.e. one thoushand and fourty five rupees.

1650