what is the difference about HART, and 4-20mA signal?

Answer Posted / mastersensor80

ANSWER NO 5 IS GOOD,the question about communication
prtotocol, how we trassfer the signal from transmitter to
the DCS,Many ways let us compare between two of them.
a/ 4 - 20 ma (conventila wiring)
b/ HART
HART use the 4 -20 ma but the communication is done via
digital this why we can view many of the transmitter
parameters,this base on PKS (phase hey shifting)refer to
modulation tecniques in communication.

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW TO CALCULATE ACCURACY OF AN INSTRUMENT. WHICH IS COMPITABLE FOR USE.

1806


What is zone,loop/fire alarm system?

2078


I have energy meter for educational project having 0.5s class but my friend need 0.2s class meter , which one is good for that purpose and what is the actual difference of that two classes , need very easy example also.??

990


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

1726


How hart protocol can be connected with control valves?

602






describe flow nozzel principle?

2076


What is the formula of vabration sesore. i mean how to covert mils to volt plz share if any body knows   very argent : my mai is merajalam143545@yahoo.com

2035


PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear

1534


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7451


How u will setup SPI(2007) on Citrix Server (Thin Client Mode)? Plz Justify?

1590


What is instrumentation technologists and mechanics?

574


how to turbine speed measurement?

1162


sir, give me placement papers and interview quistion of birla group company of copper.

2373


give eg of how I/P is used in control loops

1498


What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?

1538