What is mean by PID controller? And what is its Long form?
Answer Posted / shubham
PID controller has three controlers in it
1) proportional control- control signal U(s) directly
proportional to error E(s). just like drivers controling its
vehicle speed...jitna desired speed se variation uyna jjyada
accelerator ghumana
2)integral control- U(s) is proportional to integraof errors
uptil time T. i.e. U(s) is changed not only according to the
previous value of error but it changes with the summation of
the errors found earlier
3)derivative control- u(s) directly proportional to the rate
of change of error i.e. if rate of change of E is hhigh then
U is high and viceversa
| Is This Answer Correct ? | 14 Yes | 2 No |
Post New Answer View All Answers
can a 150 kva 3 phase 440v/230V delta-wye step down transformer can be use as step up transfoermer with connected loads at 440v side?
DG SET BLOCK DIGRAM
how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids
i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
What is the basis for selecting Vk/2 or Vk/4 for REF and Differential protection of Transformer and What is the significance of magnetising current
Can a generator runs after getting 1st stator earth fault.
electromechanical relay type identification example : type=tjmh t-stants for j- m- h-
we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.
What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control
why need to be maintain power factor for industrial customer?
Apparent power is expressed as V * I(Conjugate). Why not in V * I ?
If the rated speed of a d.c. Shunt motor is1440 r.p.m, which method of speed control would you suggested to obtain a speed of 1500 r.p.m?