why full bore ball valve is not used in steam applications?
Answer Posted / instru
Rotary valves like Ball, butterfly valves are called as
high recovery valves. High recovery means less pressure drop
ofcourse compare to Globe valves. The biggest problem with
high recovery valves is that they are prone to Cavitation.
In case of Globe valves the path is quite torturous and
hence less prone to cavitation. In case of ball valves flow
is starigh through the ball. Cavitation occurs when pressure
at the vena contract drops below the liquid vapour presure.
In case of ball valves the vena contracta pressure and inlet
pressure have marginal difference ( thats why high
recovery). When inlet pressure and vena contract pressure
are clsoe to each other valve is definetely to cavitate .
Hence Ball valves are not used in applications where
cavitation is likely to occur.
Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
What are different type of instrument cable
How to calibrate Field bus transmitter? procedure ?
Q1]IF THE RANGE FOR FLOW IS -35 TO 125 WHAT WILL BE THE SPAN FOR ABSOLUTE AND FOR NORMAL? Q2]HOW TO CALIBRATE CAPILLARY TYPE LT? Q3]HOW MANY ERROR CALCULATIONS ARE THERE USED IN PROCESS INDUSTRIES? Q4]HOW TO CALIBRATE TEMPERATURE TRANSMITTER? Q5] HOW TO CALIBRATE LEVEL TROLL AND HOW TO CONNECT? Q6]PLEASE TELL ME THE BASIC FOR INSTRUMENTATION WHICH IS APPLIED FOR CALIBRATION AND FOR ALL? PLEASE MAIL THE ANSWER TO honest_yes@yahoo.in
Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.
how to do dynolab wind speed sensor loop test, how to simulate value,i have simulate mA 4-20mA but not responding in DCS faceplate, please kindly advice me any one.
Which language of programing is popular? how can i learn it ?
what does it mean an active front end in vfd plz explain it briefly
What is eddy current? Describe the operating principle of proximity probe.
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
In which principles tx ,pressure gauge,Temp gauge,control valve works?
where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com
which processor is used in dcs.
Draw bode plot of any transfer function. Why is plotting bode necessary?
what is actual drum level and compensated drum level?
Why do we have earthing cable in branch cable and shield in the same cable?