HOW DPT WORKS?

Answer Posted / visakh

D ifferential pressure transmitter has two ports,
ie high pressure port and low pressure port , these two
ports connects to the pipeline or tank..etc by a metal
tube.the difference in pressure from the two port strikes
on the diaghpraghm inside the transmitter,then the
dighpragm get a little movement , the transducer in the
transmitter converts the mechanical movemeet to electrical
signal, ie 4-20ma

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

State four different types of flow measurement, for gas flow measurement MMSCFD is the common unit expand the unit and specify significance of word S in the unit.

1549


Emergency Shutdown Systems/ Plant Shutdown System.

1753


few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters

1609


If we increase only P what will be controller action ?

1633


What is standard procedure of manual mapping in Radar type level transmitter?

1426






Why thermo wells are used? What materials are used in thermo wells?

658


What is the use of temprature compensation?

714


Where Can i take a SPI INtools training in Mumbai? In Rolta India Ltd to whom I should approach regarding of SPI INtools Training?

2326


why any measurement made interms of pressure is more accurate ? to be more precise most of the flow velocity is made interms of pressure and it is accurate. what is the reason behind pressure measurement being accurate ?

1419


the 3 most common transmitter protocol being in refinery or qatar gas and aramco.

2488


hi my name is rakesh patel i just complited my be in instrumentation & control now i am going to working as a validation engineer in a poject department so what is a scope in a future as a validation engginer ? what line is good for me can any bady give me complete solution please? your regard rakesh patel

1520


who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.

4275


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1638


Which types of quections asked in interview for FORMULATION PLANT (PHARMA)

6220


i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in

2558