Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

i am swathi, b.tech 4th year.
In smps(switched mode power supply)we are using
diodes,mosfets,igbts for controling of current.
And my question is why we did not use thyristors(scr)? it
is also act as a switch,then what is the drawback of scr as
compared to above transisters> if we use the scr,then what
is happening ? plz give reply as soon as possible bcoz i
am doing project on smps. plz frnds i want ans for
that. if anybody know the ans plz send to my e-mail
id /swathi.tadakapally@gmail.com/

Answer Posted / prasad,clp(power)

Hi dear this is prasad from clp (power)...we can use
thyristor(scr) but for scr we have to design firing angle
circuit separatly,we have to check whether scr is
triggering or turning on exatctly as per our requirements
or not and for high power applications it is better to
diodes,mosfet,igbts..in these we wont face firing angle
circuit design problems...bocz for the SCR firing circuit
is the heart hope so....

Is This Answer Correct ?    10 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.

2367


how diside ct mf exmp.200/5 ct

2198


PLS MENTION QUESTIONS ASKED IN IOCL INTERVIEW FOR ELECTRICAL EGG??

2437


What are m circles?

1124


sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2965


how to calculate voltage drop and followed by cable calculation?is there avail in formula?

2076


What is Tachometer used to measure?

1261


what are different types of electrical windings? i know the distributed winding ,concentrated winding etc but i want some detailed information, in what condition we will use distributed,concentrated windings what are the difference between them which is best, how induced emf changes by using different types of windings 20 hours ago - 1 week left to answer

2027


what things to be considered when designing UPS

1789


at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?

2135


what is the sludge current

2140


trasnfarmaer core make

1979


what is the difference between gas group b and gas group c electrical equipment construction wise?

1883


how brushed dc motor operating ?

1903


How to know the Max. current caring capacity of the cable by its size ?