why the efficiency of the dc machine is high ,when it is
operated as a generator?
Answer Posted / guest
Effiiency of any machine is defined as the ratio of output
to the output.
Efficiency=(O/P)/(I/P)
MATHEMATICAL PROOF
Since electrical quantities are easier to measure in
comparison to mechanical quantities.
So in the determination of efficiency of DC machines,
we first find electrical quantities(input or output)and
subsequently find mechanical quantities(output or input)by
subtracting or adding the losses.
Efficiency of Generator=Output/input=(V*I)/(V*I+loss)
Efficiency of Motor = Output/input=(V*I-loss)/(V*I)
As long as machine is same, the rating and losses are not
going to change.
Clearly the ratio of above two equation is greater than 1
meaning there by efficiency of generator is greater than
motor.
PHYSICAL CIRCUIT PROOF
If we look into the circuit model,In case of generator back
emf causes less amount of current to flow through the
armature.So electrical losses(Cu loss) are less.Electrical
losses are function of current
In case of motor counter torque is produced so speed of
motor is less.So rotatinal loss(Core and friction) is
less.Rotational losses are function of speed.
Since loss:electrical loss > Mechanical loss.
So efficiency:Generator > Motor
Author:arbelectbit@yahoo.com
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
pls tell us AC plant are how do work and parts name with picture
Working of microwave oven?
if we run a 3 phase machine on two phase what will happend??? given answer with solid reason please
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com
What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer
limitation of conductor height on ground when we consider EMC
explain single phase series motor
WHERE CAN I GET THE PREVIOUS QUESTION PAPERS OF Govt Polytechnic in deee 2nd year papers
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
i am trying to PSUs/govermeant jobs since last 2 years but still i m not success, plz help me.
Why IR value of the (HT cable Plus synchronous motor) is less while individually having IR values in GΩ?
how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids
Igfet is a
A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.
How can I known multiplying factor .without multiplying table