What is the function of RCCB? What are the different
sensitivity ratings & each application?
Answer Posted / ravi
RCCB-Residual current circuit breaker.This is used in
Industrial safety purpose i.e. is to isolate the healthy
circuit whenever earth fault & overload current occurs.we
have in market at different type of ratings 30ma,100ma.as
per requirement will use above ratings.for example human
body having current flowing capacity of 30ma.so in
industrial as per safety constraint they will prefer 30ma
RCCB/ELCB.
| Is This Answer Correct ? | 27 Yes | 11 No |
Post New Answer View All Answers
Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?
what is the advantages og idmt relay over magnetic relay??
what is kvarh? Please define it With calculation General motors ?
How to determine the breaking capacity such as break down current and break down voltage for VCB and CT's.
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
what is the standard duration after failure EB power
How to select the gauge of wire for winding of motors? How to select number of turns for winding of three phase induction motor?
Are Refrigerators & Deep Freezers the Inductive load ? How to calculate the Power Factor & hence the Output Power for them ?
What are the functions of different probes used in cro?
what is the difference between neutral and earth
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
what about GD square and its important for motor design?
Explain the operation principle, advantages and disadvantages of the following converters: a) A 12 pulse converter b) A Switch-mode inverter c) A thyristor inverter
What type interview questions ask in Electrical technicians
If UG power cable both ends are to be earthed or what? If not why?