What are various power system instabilities and what are
their effects on power system operation?
Answer Posted / iamdon
There are mainly three types of power system instabilities
1)Rotor angle instability:It arises due to real power(P)
imbalance.If the situation continues for a long time there
will be mechanical problem with rotor.
2)voltage instability:It arises due to reactive power(Q)
imbalance.If the situation persists for a long time there
will be voltage collapse or Black-out situation within the
system.
3)Frequency imbalance:It is due to power generation
imbalance.If not corrected within the time limit, there will
be islanding of some part of system.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what are the major & minor faults that occur in an inverter and in UPS ? And how to repair and resolve them ?
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
how can i improve the power factor in domestic (230v)
please give me solution to rectify the emi(electromagnetic interference)
As you achieve greater success with the company after some years, Will you like to be a share holder in our company?
What is Annunciation?
how to changeover ups in this power failur time?
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?
What is the selection process of breakers. Can any one please give a formulation on same?
what is ratio of copper wire size and current ?
If we connect a motor and generator together (I mean that the generator gives the motor electricity and the motor gives the generator movement) regardless the losses. Will the generator still generate and the motor still move?
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
Explain the advantages and disadvantages of hydropower plant?
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..