Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the KVA formula of a three phase transformer

Answer Posted / m.sambasivarao

KVA= kw/pf

Is This Answer Correct ?    20 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What will be the diameter of pipe between conservation tank and transformer

1938


3phase cable calculation formula by motor load

1530


What are the section criteria for cables. Now everywhere XLPE power cable is used or PVC is also used?.

1678


if voltage bt phase & nutral is 38v in a panel board . whats the root cause.

2318


i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT

1958


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3817


If increased the frequency up to 1000 then what changes shows in voltage?

2426


what is mppt (maximum power point tracking ) and how they used in solar power generation ??? what are the main components used in mppt?????

3340


what is the purpose of bypass mode in energy lighting transformer?

2495


what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?

2129


what is the purpose of high speed earth switch in gas insulated substat

2999


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2328


What are all present producing cost of Per KWH of various Fuel?

2611


what are the types of electromagnetic forces developed in practical transformer?

2637


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2586