WHY THE WIDITH OF COLUMN IS TAKEN FOR DESIGN OF ISOLATED
FOOTING??
Answer Posted / dr.eng.mustefa
moment at the face of column is main for footing design..
even tapering may not be needed as it is done only to save
concrete as steel is required in free end
but in case of deep footings more than 1.5 feet double
reinforcement is given at top and botttom
,you know that punching force and wide beam forces are
considered; by leaving the place covered by the column
dimenshions,and taking critical sections arround the
footing. I think it is enough Answer.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is the outturn of Ceiling plastering
What is meant by dimensioning?
how to calculate load for a bungalow and 1column carry how much load if the size of column ,9"*15" .....or total structure load......
Water filter calculation formula
what is detail procedure of eccentric footing? plz. give solved exmple?
4. Differentiate between NC and OC soils. Draw curves for (i) Stress vs Strain (ii) Volume charge vs Strain (iii) Pore pressure vs Strain for these soils
Can we use Polystyrene as a Bitumen modifier !! if so is it a good MS research topic ? and what type of laboratory tests will be conducted during Research work ??
how much cement and sand required for 1cum rr masonry
what is called Bulk Density of aggregate?
Define What is the origin of name Railway Sleepers?
Define What is passive earth pressure ?
How long does it take concrete to harden?
how much is the maximum compressive strength of soil cement and soil-cement-microsilica .
What is high adherence steel bar? I have a general specification which refers to High Adherence steel bars, coils and meshes to BS EN 10080 and BS 4449 or BS 4483. Is this just general re-bar or is there something different about it? The spec originated in France.
plz.show development and anchorage length in simple diagram.