what is the differenc between A.C. and D.C, which is more
dangerious?

Answer Posted / kaushik (ms university)

In dc and ac ,dc is more dangerous. b'coz in dc there is
continuous voltage where is in ac there is alternating
cycle.so there is a moment at which ac voltage crosses the x
axis .so when there is any shock in our home then we had
just a shock for a moment

Is This Answer Correct ?    16 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks

1484


What is core CT & it's function?

1744


i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh

2660


3ph motor running with unequal kw and different pf what are the reasons

1224


What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?

1419






what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.

1494


Can anyone explain me about the capacitor calculation

1711


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1410


why capacitive load is not used in routine life????any reason is there ??????

1144


in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?

1719


What are the necessary components of the feedback control system?

732


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1467


What is advantages of VSCF wind electrical system?

1915


What is EHT tariff or Power factor Tariff ????

1910


at work i have a genertor/alternater what is the easyest way to work out if it is dc or ac?