what is LA CT PT panel?

Answer Posted / nishad

LA - lightnig arrester: it is use to protect the equpment /
system from dangerous atmospheric lightining.

CT - Current transformer:we can't talk load out put
directly to the meassuring equipmet from the load line. We
use CT for that purpose. It is useing for meassuring the
load current & other meassuring Data( Ampere, KW/KVA, PF
etc).In the cause of protection CT is very essential, such
as over load ( solid state OLR - CT through) Earth fault,
Differetial Protection etc.... WE need CT's servies in Both
LT / HT.
PT - potential transformer:It is also useing for meassuring
the voltage & other meassuring Data( KW/KVA, PF, HZ etc).In
the cause of protection PT is also very essential,such as
under voltage,over voltage, Under HZ, OVER HZ etc... we
can't take the reading directly from the line in cause of
HT so we are usein PT.WE need PT's servies in Both LT / HT.

Is This Answer Correct ?    31 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In synchronous motor, how the field current is related to armature current..i know its inversely proportional..but concept wise...i was nt clear....pls help me...

1578


What is the difference between the relay and the circuit breaker?

613


how to decide choke rating for drive?

1884


What willbe change in programming when we use 5/3 solenoid inplace of 5/2 in operating of a cylinder?

1616


i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.

1785






i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh

2660


can anybody sent me power grid questions. what subject should i prefer for preparation?

1649


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1447


sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.

1788


What is the need for a controller?

664


how we decide scurt (disc) of insulator with respect to kv rating

2921


Describe the colour rendering properties of i) tungsten filament lamps ii) tubular fluorescent lamp

2626


ACB & VCB how do work and saftes and how can maintenance in this and parts name show with picture

1635


Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?

1679


What is the role of Dedicated earthing in UPS System?

2640