Can Induction motor run at over rated speed? ( 15oo rpm is
rated speed for 50HZ. is it possible to ride 3000 RPM with
same motor with the help of VVVFD for continues ride of
100HZ)

Answer Posted / predator

Dear How is it possible, Because the company give the rated
speed to that motor is 1500RPM. If we increase the speed to
3000RPM WRT VVVF, that speed should affect it's whole life,
means gradually damaged the motor's bearing, windings
thanks

Is This Answer Correct ?    9 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1459


why do we carry out winding resistance test?

1847


In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.

1503


errection check list for transformer maintenance

2187


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1495






what is the difference between 2 way and 4 pole selector switch???

1874


Define the term factor of inertia.

1453


Why strting torqe high in inducation motor?

1652


Working of microwave oven?

1795


why US countries maintains 110v and 60HZ

1735


why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)

1480


How to calculate the value of earth capacitance in a transmission line.

1799


In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)

1306


which is the best institute for PLC,SCADA,DCS in hyderabad

1895


WHAT ARE THE DATAS REQUIRED FOR PROTECTION AND METERING AND CONTROL AND LOGIC PREPARATION,HOW TO STUDY THE PROTECTION AND METERING?

1696