Answer Posted / siddharth
minimum in IDMT refers to the minimum time.IDMT is relay
which has a characteristic of detecting a fault..ib which
the operating time has an inverse relationship with
magnitude of fault current.and the relay is such designed
that within a given time it has to trip the CB.thats whhy it
is called inverse definite medium time relay.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Explain mechanical rotational system?
if the motor rated speed is 950rpm. how to change the above rated speed? is it possible?
It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.
what is transistors comprised of?
Why syn. Generators are used for the production of electricity?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.
how we can calculate power factor in single phase & three phase ?thank u
why do we have spikes enough to burn electronic boards, when generators are not grounded
Pl.brief me about Electrical power distribution system from Main generating station to Industry.What is the use of in between station.
how to calculate percentage impedence at 75 deg C at normal tap
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
How to control motor gearbox speed and friquency? If length of cable and dia given, how to measure the voltage drop?
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
What is the Minimum winding resistance of motors ( small & big)? referance range