Answer Posted / hari hajare
Crawling in an induction motor is caused by low supply
voltage, high loads, development of harmonics in the rotor,
possibly even design faults. Crawling can be caused when a
small change in load results in an angular displacement of
the rotor field with respect to the stator field a bit
similar to the synchronous motor operation. The effects of
crawling can be reduced by avoiding certain combinations of
stator and rotor slots or altering the position of rotor
bars(skewing).
Is This Answer Correct ? | 12 Yes | 5 No |
Post New Answer View All Answers
how to test reverse power trip?
What happens to voltage when current is zero?
Which do you think is the most significant cause of energy loss in a factory?
how generator load test is conducted?what are the steps?
Why do we need a separate control desk & PLC control panel in Boiler plant or coal handling plant? Can we provide cost effective Control desk cum PLC panel. Is there is an specific need for control desk.. kindly advice.
What is the difference between single point and double point bonding. please kindly detail about bonding of cables.
Why mostly the HV side of transformer has Delta?
can you plz send l&t aptitude questions if available its urgent plz plz plz
iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.
What is core CT & it's function?
HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?
magnetizer priciple
describe the Tranformer testing procedure
Refernce currents are to be generated using refernce cueernts how can this be done
What is Traction? 1KVA Alternator, How much urrent taken?