Answer Posted / hari hajare
Crawling in an induction motor is caused by low supply
voltage, high loads, development of harmonics in the rotor,
possibly even design faults. Crawling can be caused when a
small change in load results in an angular displacement of
the rotor field with respect to the stator field a bit
similar to the synchronous motor operation. The effects of
crawling can be reduced by avoiding certain combinations of
stator and rotor slots or altering the position of rotor
bars(skewing).
| Is This Answer Correct ? | 12 Yes | 5 No |
Post New Answer View All Answers
If a air condition consume 2.50 to 3.00 amp then how much it will consume in watts if it is running 10 hours out of 24 hours????
How could a garment factory benefit from renewable energy
what is the function of anti pumping relays? what is KVAR? How it is generated in alternator? What is 3rd Harmonics? What is IDMT relay?
How one may guess the direction from which the distribution line is incoming if there is no pole plate on poles?
how to calculate fuse rating for a motor
Why to keep capacitor bank off while generator running.
what is servo motor & how does it work.
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
What is value of earth resistance required for substation and equipment earthing and what are the reference guidelines
Electronic circuit
how define the torque in ac drive. from electrical side in the drive friquency ,voltage and current three factor is there.
what do u understand from filter factor of reactor?
can you please send me the technical questions and aptitude questions of honeywell and jindal steel electrical engg. question paper my e-mail ID is(kkesavanraj@gmail.com)
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
what is saturation kit?which use above 15 kw motors panel side.