I am an electrical contractor in noida, I am registereg in
noida vat. i got a contract in Delhi State, my party told
me that we shall deduct WCT @4% & reimburse Service tax all
in composite scheme.
Now Problem is this,
1 Can i able to purchase outside the delhi?
2 Can i produce a c form to our vendors?
3 What is limitation of purchase from outside the Delhi?
4 What % of tax Govt will levied upon me?
5 How can i take credit of tax paid upon purchase made by
us.
So, like these type questions i have in my mind if any
person know the right answer please write to
sksproj@gmail.com or contact me on - 8010076534 /
9212758177 / 9718378190.
Thanks with Best Regards,
S.K.Saxena
Answer Posted / agd
contact TAX CONSULTANT.......simple
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
how to calculate cable size in diffrent loads?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
redundant connection in contactor?
please send me previous year questions of jspl through which i could prepare myself for the test.
how to find the resistance and gap volatage of the diode??
what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering
WHAT IS DIFFERENCE BETWEEN CAPACITOR AND CAPACITANCE?
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
Transformer how to maintaince a check b check c check d check
pre arcing time of ehv breaker
Define demand factor?
How to dimensioning SDCCH, LAPD and CS7 signaling on GSM?
what is W.T?specify the acceptable range?
Is there any abbrevation for STUB in Stub bus protection
what do u understand from filter factor of reactor?