which one is dangerous AC Power r DC Power for Electrical
Shock ?
Answer Posted / sandeep
DC is more dangerous because in AC current becomes zero 3
times in second so at that time there is great chance that
person can be separated from line thats why you alwase find
that persone getting shock gets thrown away from live
contact if he gets certain resistance due to touching of
wood or any insulating material but on other hand DC has
constan current so no chance of it becoming zero and no
chance of escape as mentioned above
| Is This Answer Correct ? | 34 Yes | 0 No |
Post New Answer View All Answers
what is the advantage of connecting capacitors in delta than in star?
how to control the speed to switched reluctance motor
Where can I get CPWD electrical specifications & Shedule of rates? Please help me
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
why swinburnes test cannot be performed on series machines?explain
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
what is the thumb rule for determination resistance of resistor?
how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer
What is Surge Capacitor? Why it is require in Generator Circuit Breaker,inspite of surge arrester?
what is the use of sdf?
what is kvarh? Please define it With calculation General motors ?
Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
Safety of dry type transformer