Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the diff btw Conventional & Addressable Fire Alarm
System???

Answer Posted / s.gnanaprakasam

In addition to manivannan's answer i want to add one more
point.In conventional system all detectors in one zone were
connected in one straight line.so, if there is any failure
of one detecter in that line means futher detectors will
not get power and they will not work.
But in addressable also known as inteligent fire
alarm system, all detectors in the zone were connected
insame type of conventional system with small different is
thetail end detector's another end[one end is with previous
detector] is connected to fire alarm. In such a way all
detectors were in one closed loop.so,is there is any
failure in any detector means other detectors adjacent to
faulty detector may get power supply from other end of the
loop.Hence reliability of the system increases.

Is This Answer Correct ?    45 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

ho can we calculate the conductor insulation value according to their ratings like voltage,current etc.how insulation value related with voltage,current and power of amachine

2122


Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?

1419


what is the disadvantages of common earthing for AC and DC equipment? (i am talking about inverter control room and inverter duty transformer earthing is common...?)

1686


The loads are connected with phase and ground then why current flow as the loads ?

1983


hi Is there any possibilities to find out the rotation of a shaft or something else by using electromagnectic waves or by IR rays.If s then can v change the dir., of rotation of the same by remotely?& how? plz dn't any1 say "NO r CAN'T"

2107


Why a tesa lamp is glow between two phase?

2019


I have experienced electrical maintenance HT ,but I completed be ECE ....can I apply c license or not ???? Pls help me friend s...

1582


how does the thyistor work in dc drive?

1999


what exactly commisioning work does in electrical site work... LT side?..

1954


Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

2192


How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?

1952


Explain cmrr?

1137


how to calculate short circuit current for the busbar

1519


WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.

2710


What is the selection process of breakers. Can any one please give a formulation on same?

2170