what is the frequency standard with tolerance level for India?

Answer Posted / chandu

as per indian standerds frequency is 50Hz with
+5% or -5% of variation.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?

1825


What is power in wattage of 8.5 TR AC

1195


What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.

902


Determine the BTU size of an aircon for 20 sq metre room

1453


hi there i am highly enthusiastic about discussing electrical concepts , and hence i wud lyk to invit al do intrested to join me at gtalk and hav a dscussun of the concepts , ad me as a freind . my email id is rakesh.2k99@gmail.com

1641






hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly

1544


clarify types of motor operated valves and advantages

1471


Is there any abbrevation for STUB in Stub bus protection

1495


What will be the diameter of pipe between conservation tank and transformer

1462


in 132kv substation CRT means

2208


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1670


What are the types of the glands and difference between single and double compression type of cable Glands.

1625


How does a battary stores charge in it? please explain in simple manner and in detail.thanks

1536


How many types of interlocking use in screw type air compressor,make-Kaser(BSD MODEL)?

1605


why fractional pitch winding generally used in alternators?

2457