what is the difference between brushed
alternator ,brushless alternator & permanent alternator ?

Answer Posted / santosh kawade

Brushed alternator: In brushed alternator DC voltage for
field excitation (located on rotar) is provided from DC
source through contacts of slip ring and brushes.

Brushless alternators: In brushless alternator DC voltage
for field excitation (located on rotar) is supply through
rotating bridge rectifire (located on rotar) and high
frequency ac supply which is generated in winding which is
also located on rotar.
To provide excitation supply for main alternator field
winding we are not require to use brush hence it is called
brushless alternator.

Permanent magnet alternator: This type of alternators are
usually small capacity alternators, for this permanent
magnet is place on rotar hence we are not require to
provide any field magnetisation supply.

Santosh Kawade
9224 69 3116

Is This Answer Correct ?    39 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In what condition the HT fuse breakes?

1484


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1241


What do you mean by the zone of protection?

619


i need some project topics along with circuit diagram in the electrical adnd electronics engg and also give ome website regarding projects.my mail id is thenmozhi2k7@gmail.com .please help me.

1443


what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?

1426






If ROC does not lies inside unit circle,then ? a) Fourier transform converges b) Z transform converges c) Hatly transform converges d) Colpit Transform converges.

1840


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

1809


How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.

1333


the problem faced on star or delta winding connection??

1497


how can we design robots

1455


From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer

933


HOW MANY TYPES OF FUSE?

1643


why booster transformer is used in sumpners test conducted on transformer????

3081


checking procedure of capacitor based motors.used in fans etc?

1611


what is the importance of Partial Dischage test for Electrical Equipments

1465