Answer Posted / suresh
kva means kilo volt ampere it is nothing but the apparant
power that means it is the total power.
kvar means kilo volt ampere reactive it is nothing but the
wstage power.
kw means kilo watt it is nothing but the real power that
means it is the useful power.
kva is the sum of kvar & kw
Is This Answer Correct ? | 24 Yes | 0 No |
Post New Answer View All Answers
Hoe do calculate the Cable size for Amps rating ?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What is CCT (Correlated Color Temperature) ?
testing of Vector Group – YNaoD II
given data are load current & power factor cable core size? plz any one update the calculation formula
Name a govt approved university which have 100% online engineering course.
why are distributed windings generally used in alternators?
I want to know the 'Test voltage' for Tandelta testing of 3.3 / 6.6 / 11 KV Motors. Please explain
Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not
What is the abbreviation of NGT panel
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
What is Electrical Grade Aluminum for Tubular BusBars. i am confused between 6063 and T6 or T5 and what is BS 2898 and BS 159?
what is residuel magnetism. and how order lead acid batteries for 24 volt. emergency lighting system.
What happens if we run alternator on under frequency?
explain the types of drives