Answer Posted / alianwar
In electrical engineering, ground or earth may be the
reference point in an electrical circuit from which other
voltages are measured, or a common return path for electric
current, or a direct physical connection to the Earth.
Electrical circuits may be connected to ground (earth) for
several reasons. In mains powered equipment, exposed metal
parts are connected to ground to prevent contact with a
dangerous voltage if electrical insulation fails. A
connection to ground limits the voltage built up between
power circuits and the earth, protecting circuit insulation
from damage due to excessive voltage. Connections to ground
limits the build-up of static electricity when handling
flammable products or when repairing electronic devices. In
some telegraph and power transmission circuits, the earth
itself can be used as one conductor of the circuit, saving
the cost of installing a separate return conductor.
For measurement purposes, the Earth serves as a
(reasonably) constant potential reference against which
other potentials can be measured. An electrical ground
system should have an appropriate current-carrying
capability in order to serve as an adequate zero-voltage
reference level. In electronic circuit theory, a "ground"
is usually idealized as an infinite source or sink for
charge, which can absorb an unlimited amount of current
without changing its potential. Where a ground connection
has a significant resistance, the approximation of zero
potential is no longer valid. Stray voltages or earth
potential rise effects will occur, which may create noise
in signals or if large enough will produce an electric
shock hazard.
The use of the term ground (or earth) is so common in
electrical and electronics applications that circuits in
vehicles such as ships, aircraft, and spacecraft may be
spoken of as having a "ground" connection without any
actual connection to the Earth.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION
Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer
After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.
-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.
why zero sequence impedance measurement is not applicable for single phase GT
Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above
How many kw will suply from one db
what is ATS & RING MAIN UNIT in Distribution System?And its Function.
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
how a resistor resists to flow the current?how an inductor oppses the sudden change in current?how a capacitor opposes a DC voltage.
What is power in wattage of 8.5 TR AC
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
What products have you designed which have entered high volume production?
I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)
I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.