My question may be very basic or childish but this question
still persists in me, someone plz help me
1.why do we go for differential equations to analyze a system?
2.why do we solve it using matrices, is there any specific
reason for using matrices other than the stories like it is
simple,faster etc.
Answer Posted / h v k kumar,mtech,instrumentat
if u model the any system like
mmechnical/electrical/pneumatic establish relation b/w
input and o/p force,mass,friction etc a=dv/dt,f=m(dv/dt)
model all forces and adding all forces we get diff equation
homo/non hom solve by using laplace trnsformation.but here
initial conditions assumed to be zero solution is state
space analysis using matlab ,so matlab variables are
arrngend matrix format.
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure
what is sil (safety integrity level
What is Erosion in a control valve?
we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.
1- Explain about HPM 2- What is the FSC and explain the configuration of FSC 3- explain the complete loop of vibration, how it works (field to control room) 4- What is the use of proxymitter? 5- During job your partner effected with H2S then what you have to do. 6- what type of gland packing uses when valve glind is leaking.
please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...
what is span value and zero ? and how set ?
Describe the typical instrumentation used in monitoring the performance of a shell and tube heat exchanger.
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
What is hp & mp seperator .& what is its working principle ?
Instrumentation symbols interpration, P& ID, Logic diagram analysis, Electrical drawing analysis.
WHAT IS TMXT IN TEMPERATURE FOUNDATION FIELDBUS.
what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?