Can transformer develop three phase power from a single
phase source?

Answer Posted / naveen kumar mishra

A transformer acn not develop three phase power from a
single
phase source.
deu to===========
01)-single phase has only one phase syquence.
02)-a three phase transformer has three phase primary
winding it need three phase rotating magnatic field that
can not achive bu a single phase source.
03)-if we will apply single phase source at three phase
transformer,s primary winding then only one primary coil
will exited for inducting so we can achive only single
phase power output.

Is This Answer Correct ?    20 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

types of central Air conditioner plant?

1712


what is the effect of higher value of GD???

1345


how balanced in star delta connection ?

1634


How relay coordination has to be done? what are the inputs are required for this? Please explain this with calculation method?

1352


how to increase or decrease speed in DC shunt motor by DC convertor

1727






what is static frequency converter?what is the function...of sfc...?

1763


What is mean by STUB protection?

1580


Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards

1642


why i can not use thimble on capacitor duty contactor

888


I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?

1786


What will be the effect of circulating current in HT xlpe cable when both the armour ends are grounded. Will the termination fils after some time in case of 33 kv supply.

1631


how we control automatic generator i'e with to supply (main supply and local generator) when the main supply was break to supply the local supply automatically to begin supplying power.I now this control circuit is the combination of contactor time delay contactor switch and overload relay .but my question is how we combine those component thank you

1514


What is VSCF windelectrical system?

1352


What is inrush current?

645


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1396