How the size of transformer decreases if we increases the
frequency?
Answer Posted / jagadeesh
e=4.44*F*N1*(Bmax*A)
freq increases then Bmax increases
but product of Bmax and A constent then automatically decreases
Is This Answer Correct ? | 2 Yes | 5 No |
Post New Answer View All Answers
in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)
If one tertiary phase i.e. R,Y or B is earthed of a loaded type tertiary delta connected (Without load)of a power auto transformer, what is its advantage/disadvantage?
54 Comments Alok and Bhanu play the following min-max game. Given the expression N = 38 + X*(Y – Z) where X, Y and Z are variables representing single digits (0 to 9), Alok would like to maximize N while Bhanu would like to minimize it. Towards this end, Alok chooses a single digit number and Bhanu substitutes this for a variable of her choice (X, Y or Z). Alok then chooses the next value and Bhanu, the variable to substitute the value. Finally Alok proposes the value for the remaining variable. Assuming both play to their optimal strategies, the value of N at the end of the game would be?
in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?
why lightning arrestor are made in two stack of insulator but why not cvt
How to calculate no of EARTH PIT? Describe the formula as per IS standard?
What is corkscrew rule?
what is the difference between 50 hz freq. and 60 hz freq.? which is better and economic in them ?
Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?
what is meant by brushed alternator & its working principle ?
How select ELCB for 32amp. socket having quantity 12Nos. We have to do this wiring in PLANT. Please Also explain the incoming cable specification.
Anybody know how schematic diagram for reverse power relay? RPR for generator protection
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
how oti and wti connections are different from each other?
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you