why nearly all the voltage levels are in the multiples of 11
like 3.3 ,6.6 ,33 ,11 kv.....
Answer Posted / ashi
its due to form factor
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
what is the difference between STAR and DELTA connection and application wise how it can be utilizedd
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
tan delta equation test on alternators
Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
what is conductor constant of raccun conductor
List the advantages of star-delta starter with induction motor?
List examples of voltage source?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
how can we select the appropriate VCB ?
please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com
dear sir, i completed diploma in electrical in 2005, how i can get electrical supervisor liance in mumbai
in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain
For an induction motor wat is the loading/unloading cycle duration or interms of L/UL ratio/ percentage?