What is the diffirence between Earth and Neutral
and What is the required normal voltage between earth and
neutral
Answer Posted / jasmeet
The voltage difference should be idealy zero but
practically it depends upon application. Normally it should
not be more than 5 Volts.
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
Calibration of controller (pneumatic)
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
What is the cascade control
Draw a simple circuit for a well head control panel used to protect the well against fire, leak, blockage, ESD, & controls the operation of one downhole & one surface safety valve. Explain the operation and controls
Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.
Why humidity limit is 30 to 55 % for raw material storage?
how can use ram
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
what is sil (safety integrity level
all types instrumentation questions want
Q- What are the application in which PNP transistor is preferred over NPN ?
key phaser where is use and work
Using your own examples solve a problem involving normal table. (experimental method and analysis)