When VFD is connected to a 3 phase main supply there is
load current difference between incomer to VFD and outgoing
from VFD.
Answer Posted / pinak
sir,first tell me by what instrument you are measuring the
current,probably clamp meter.the thing is like that in case
of VFD's the incoming frequency is not same as the outgoing
frequency.so due to this change in frequency the current do
changes. sir i hope if you just supply 50Hz on incomming
siode and from the output you are also taking 50 Hz then
the current doesnot changes.
Is This Answer Correct ? | 9 Yes | 5 No |
Post New Answer View All Answers
why we testing the core balance of the transformer before comissioning?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?
What id difference between power and energy?
What type interview questions ask in Electrical technicians
Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
What is a system?
How phase to phase voltage comes 440V.
Explain the fundamental difference between emf (electro motive force) and pd (potential difference) ?
How generating electric power export to grid from the generating station ?
HOW TO CALCULATE S/C,O/C,E/F OF ACB.
please anybody help me to find out the BHEL trainee Exam previous year questions papers . if u ve pls. send it to surekhared@gmail.com
How to protect a Dosing pumps/any sensitive equipment (single phase) from surge protection inside a food factory.
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
what happend to DC shunt motor if its field winding insulation becomes slightly weak? will that motor can run on full load or not explain in detail. thanks